Isc & Voc Monitoring

Descripción

The ISC & VOC monitoring system is developed and manufactured by Kintech Engineering to accurately measure the Isc and Voc values of two solar PV panels simultaneously. It is used for detection of fault symptoms, analysis of solar panel degradation and inclement weather conditions on the solar panels installed in the solar PV plant, including the effect from soiling.

Case Study 2

Norway

Case Study 6

Germany

Case Study 7

Egypt

¿CÓMO PODEMOS AYUDARTE?

Dinos que necesitas rellenando el siguiente formulario y nos pondremos en contacto.



Categoría:

With its small form factor, the Isc & Voc device is meant for use on solar PV panels already installed in the solar PV plant. The device can measure the Isc and Voc values from up to two solar PV panels simultaneously and when supplied as part of a complete measurement kit (including the Orbit 360 data logger) an open-source python script can be included to calculate the soiling rate.

Applications

Isc & Voc monitoring of solar PV panels. The Isc output can be used for irradiance calculations whereas the Voc output can be used for cell temperature calculations. The combination of both Isc and Voc outputs can be used to estimate the solar power output.

GENERAL
Supply voltage11.5…30 V (DC)
Average current consumption10mA @ 24V
Peak current consumption500mA @ 24V
Operating temperature-30…+70ºC
Storage temperature-30…+85ºC
Dimension72 mm x 89.7 mm x 62.2 mm
MountingStandard DIN Rail
IPIP10
CompatibilityAll Kintech Engineering data loggers
ManufacturerKintech Engineering
ISC MEASUREMENT
Isc input range0..20A*
Accuracy0.1%
Analog Isc Output0…5V
Transfer functionSlope: 4, Offset: 0
VOC MEASUREMENT
Voc input range0..60V*
Accuracy0.1%
Analog Voc Output0…5V
Transfer functionSlope: 12, Offset: 0

Solicitud de llamada

Rellene el formulario y le devolveremos la llamada lo antes posible.

Enter your keyword